New and used Molecular Devices VersaMax's for sale on LabX. With an innovative range of options, this versatile reader gives diagnostic and research laboratories all the features they need for high throughput of absorbance assays. CVs were shown to be less than 5% for all standards, well below the test reproducibility guideline SpectraMax Mini Reader Plug-In Download Page (required for SoftMax Pro 7. absorbance readers. Manufacturer: Molecular Devices; Molecular Devices VersaMax Microplate Reader with Toughbook and Software This item has been tested and is in proper working condition Wavelength Range – 340–850 nm Wavelength Selection – Monochromator, tunable i. . The SpectraMax ® M3, M4, M5, and M5 e Microplate Readers are a series of dual-monochromator, multidetection, multi-mode instruments with a triple-mode cuvette port and 6-well to 384-well microplate reading capability. Key applications: ELISA, nucleic acid, endotoxin testing. This UV-visible absorbance microplate reader provides ultrafast, full spectral range detection for cuvettes, 96-well, and 384-well microplates, with the only temperature-independent method for pathlength correction. The Versamax Microplate Reader is built around a grating monochromator. 1-4 VERSAmax Tunable Microplate Reader Operator™s Manual Component Description The main components of the VERSAmax are: Ł The control panel Ł The microplate drawer Ł The back panel (connections and power switch) Figure 1. The all-in-one data acquisition and analysis of SoftMax Pro GxP Software for use with the VersaMax Reader minimizes the risks and costs associated with transferring data. With aVersamax microplate reader Afford Able The robot-compatible VersaMax Reader is cost-effective—users never have to buy filters. Molecular Devices VersaMax Absorbance (UV/Vis) Elisa Microplate Reader For Sale for Plate Reader is complete with computer, SoftMa. All service plan coverage will end by December 31, 2028. Microplate Readers Biotek ELx808 Microplate Reader Absorbance. This technical note is designed to provide information . Wide range of applications The VersaMax reader covers. Add to Cart. Locate the User Guide on your SoftMax Pro computer for version 6 and version 7. Robust, high-value microplate readers that can run samples based on pre-defined protocols and standard filter modes cover the entire visible range for a variety of assays. 0 out of 5 $ 4,499. And the VERSAmax reader is robotics-compatible. VersaMax,SpectraMax340PC384,190,Plus384MicroplateReadersUserGuide 11 0112-0126B Theguidelinesforcuvetteuseintheinstrumentarethesameasthosethatapplytoany high-qualityspectrophotometer. Spectramax Plus 384 Spectramax 190 Spectramax 340PC384 Versamax Microplate Spectrophotometers; A Fluorescence Correlation Spectrometer for Measurements in Cuvettes. Molecular Devices VersaMax Microplate Reader. no. Tecan ULTRA Multimode Microplate Reader , Tecan, Used fluorescence plate reader. SpectraMax Paradigm. AN AFFORDABLE, TUNABLE MICROPLATE READER FOR 96-WELL FORMAT VersaMax Microplate Reader AFFORDABLE The robot-compatible VersaMax Reader is cost-effective—users never have to buy filters. Detailed specifications of each model reader are reported in Section 7, “Specifications”. Pyroplate® 96-well microplate (ACC Catalog No. The Pyrochrome Assay together with the VersaMax Microplate Reader offers a sensitive and specific method for detecting endotoxin contamination in the production process. Read up to 2 wavelengths in endpoint or kinetic mode for 96-well plates. Molecular Devices SpectraMax M5e Microplate Reader. Though it is seen that some of the microplate readers operate in the ultraviolet range for the analysis. Softmax Pro 소프트웨어가 포함된 PC 워크스테이션 포함. AN AFFORDABLE, TUNABLE MICROPLATE READER FOR 96-WELL FORMAT VersaMax Microplate Reader AFFORDABLE The robot-compatible VersaMax Reader is cost-effective—users never have to buy filters. The temperature of the microplate chamber can be regulated, if desired from 4°C above ambient to 45°C. Taking into account the price differences between each seller and each country. . Gaussia-firefly luciferase dual assays. Molecular Devices Microplate Reader Spectramax 384 340PC. used. A. Some high-end microplate readers are fitted with an automatic PPC facility which normalises microplate output so that it matches values. The Molecular Devices VersaMax microplate spectrophotometer provides rapid and sensitive measurements for a variety of analytes across a wide range of concentrations. Microplate readers read biological, chemical or physical events that occur on a microtiter plate. Read one sample or up to 384 in a single plate read using any standard cuvette, or 96- or 384-well microplate. Document Name: Framingham Heart Study Inflammatory Markers Manual, Offspring Cohort Exam 8, Omni Gen 1 Cohort Exam 3 Document Accession: phd004201. AN AFFORDABLE, TUNABLE MICROPLATE READER FOR 96-WELL FORMAT VersaMax Microplate Reader AFFORDABLE The robot-compatible VersaMax Reader is cost-effective—users never have to buy filters. The CellTiter-Glo assay was performed according to the manufacturing protocol. Microplate Capacity. BioTek Microplate Reader. The microplate remains stationary during the entire reading cycle, reducing the. Microplate readers read biological, chemical or physical events that occur on a microtiter plate. Put 200 µL sample into one or more wells of a microplate and 200 µL buffer or solvent into one or more other wells. Features/Specifications Includes PC Workstation w/ Softmax Pro Software Wavelength Range (nm): 340–850 Wavelength Accuracy: < ±0. Call 1-800-745-2710. 1. The microplate reader also has diffracting gratings to interpret results. Hamilton offers the flexibility to integrate industry-leading microplate washers and absorbance readers to enable a completely automated solution from loading samples through reading assay plates. APPLICATION NOTE. 9000-0756. Lysotracker probes (Invitrogen) were used to track acidic organelles in the RAW 264. The instrument reads any standard cuvette, microcuvette, test tube or 96- and 384-well standard or UV transparent microplate over a full 190 to 1000. This reader's dual monochromators for. Wavelength Range. Five preferred modes for diverse bioresearch applications. Pyroplate® 96-well microplate (ACC Catalog No. 000 Euro/Dollars for a high-end multi-mode microplate reader with several detection modes and the best technology for highest sensitivity and fastest detection. The Gemini XS can read a variety of sample formats from 6- to 384-well microplates in endpoint, kinetic, spectral scan, and well scan modes. VersaMax ELISA Microplate Reader. . The VersaMax reader covers a wide range of applications: Microbial Growth/MIC • IC 50 /LD 50 • Endpoint ELISAs/EIA • Cytoproliferation/Cytotoxicity • Colorimetric Protein •. VERSAmax Tunable Microplate Reader Operator™s Manual iii Labor and Parts To obtain warranty service during the applicable warranty period, you must take the product or de-liver the product properly packaged in the original shipping materials and carton to an authorized Molecular Devices Corporation service facility. Molecular Devices VersaMax Microplate Reader Thermo Scientific NanoDrop 2000 Spectrophotometer Eppendorf BioPhotometer Plus Model #6132 Agilent G1120A Multicell Transport for 8453 Spectrophotometer. Select Start>Control panel>Device Manager. Microplate Readers BioTek Epoch 2 Microplate. The eight-channel system consists of 8 sample beams and 8 reference beams, delivering both superior precision and speed of reading across the microplate. Robust, high-value microplate readers that can run samples based on pre-defined protocols and standard filter modes cover the entire visible range for a variety of assays. Wells containing cells but no BrdU label were used to subtract the background absorbances and the percentage increase/decrease in. VersaMax™ Microplate reader (Molecular Devices) 7. Page 1 SpectraMax M3, M4, M5, and M5 ® Multi-Mode Microplate Readers User Guide 0112-0115 F July 2010. It provides ready-to-run protocols, analysis algorithms, and 21 different curve fit options. 2 - 3. The VersaMax Absorbance Microplate Reader allows for selection of up to two wavelengths at a time for absorbance detection in the visible wavelength range (340 nm - 850 nm). Two different enzyme preparations (E1 and E2) were kindly provided by the working group of Prof. select to compare. by the Veritas™ Microplate Luminometer make it highly suited for the Dual-Luciferase® Reporter (DLR) Assay application. Therefore you need to ask a physicist. In this step-by-step video tutorial, you will learn how to set up your Sunrise™ microplate reader and install the Magellan™ software. 00 . 1% or ±0. ~ Bio-Tek ELx808 Microplate Reader $2,795. Detailed speciÞcations of each model reader are reported in Section 7, ÒSpeciÞcationsÓ. Tunable, filterless flexibility The VersaMax reader uses a grating monochromator to select the wavelength, so the exact wavelength needed can be selected for every assay. 00 USD. This video, part of the BMG LABTECH Video Training Series, shows you how to design your wells with samples, standards, & blanks for your BMG LABTECH micropla. Get the most out of SoftMax Pro. VersaMax™ absorbance readers typical applications for Molecular Devices microplate readers. The VersaMax™ Microplate Reader from Molecular Devices bridges the gap between the affordability of filter-based readers and the flexibility offered by monochrome-based systems. Microplate readers read biological, chemical or physical events that occur on a microtiter plate. A wide range of assays can be performed using a microplate reader including ELISAs, protein cell growth assays, nucleic acid and protein quantification, enzyme activity measurement, immunoassays, and screening of drug compounds and targets, among. Simultaneous use of the software on three (3) additional computers (in addition to the computer controlling the instrument, if applicable)Molecular Devices Versamax Tunable Microplate Reader Temperature range: 4°C above ambient to 45°C Wavelength range: 340 – 850nm 96-well microplates Sold as-is The Molecular Devices VersaMax microplate spectrophotometer provides rapid and sensitive measurements of a variety of analytes across a wide range of concentratiThe SpectraMax Plus 384 Microplate Spectrophotometer is a versatile and reliable instrument that can measure absorbance in the UV and visible range. Additionally, the VersaMax™ Microplate Reader can be seamlessly integrated with the StakMax® Microplate Handling Stacker through the. The VersaMaxTM Microplate Reader from Molecular Devices bridges the gap between the affordability of filter-based readers and the flexibility of monochromator-based systems. This technical note is designed to provide information . The SpectraTest® ABS1. . Multiple-point well scanning optimizes cell-based assay sensitivity. 9 stars - 1134 reviewsSearch Results for Versa Max Microplate Reader on Bioz, providing objective ratings for all products used in life science research. Tunable, filterless flexibility The VersaMax reader uses a grating monochromator to select the wavelength, so the exact wavelength needed can be selected for every assay. SoftMax Pro Software. A wide range of assays can be performed using a microplate reader including ELISAs, protein cell growth assays, nucleic acid and protein quantification, enzyme activity measurement, immunoassays, and screening of drug compounds and targets, among. Built around a grating monochromator, the VersaMax™ Absorbance Microplate Reader allows for selection of up to two wavelengths at a time for absorbance detection in the visible wavelength range (340–850nm). 단일 튜브 디스펜싱에서 전체 96 및 384 well 플레이트세척까지. Therefore we were taught to work strictly in the range of about 0. Robust, high-value microplate readers that can run samples based on pre-defined protocols and standard filter modes cover the entire. 2. SoftMax® Pro Software is the most published microplate reader control and data analysis software in the industry. SpectraMax Microplate Readers. Model : VersaMax . 1 Documentmolecular devices versamax microplate reader; commercial kit including all reagents; vendor: oxis (cat. This technical note is designed to provide information . 1) All parts of the MAXline Microplate Reader excluding the lamp assembly are warranted for a period of one (1) year from the original date of delivery. SoftMax Pro 5 GxP Software provides all the data collection and analysis tools of the standard edition, along withThe Molecular Devices SpectraMax M3 Multi-Mode Microplate Reader is a dual-monochromator, multi-detection microplate reader with full spectral range detection for cuvettes and 6-, 12-, 24-, 48-, 96-, and 384-well. The VersaMax and SpectraMax 190 read 96-well microplates. Tunable, Filterless Flexibility The VersaMax reader uses a grating monochromator to select the wavelength, so the exact wavelength needed can be selected for every assay. WinKQCL ® Software guides the user through the process of setting up a microplate template and running an assay to determine the amount of endotoxin in a sample solution. 04-b1-20402) units: pmol/l; minimum detectable dose: . Molecular Devices VersaMax Microplate Reader (ZB64) . FRAP. Model: VERSA MAX. Choose the microplate reader that best suits your research needs Thermo Scientific™ microplate readers provide flexibility, performance, and ease of use for a variety of microplate assays. . Wide range of applications The VersaMax reader covers. Read more. Our microplate readers and software are the industry’s most cited and have empowered life science researchers to advance protein and cell biology. 0 out of 5 $ 1,999. Molecular Devices SpectraMax M5e Microplate Reader. 4. Simultaneous use of the software on three (3) additional computers (in addition to the computer controlling the instrument, if applicable) Molecular Devices Versamax Tunable Microplate Reader Temperature range: 4°C above ambient to 45°C Wavelength range: 340 – 850nm 96-well microplates Sold as-is The Molecular Devices VersaMax microplate spectrophotometer provides rapid and sensitive measurements of a variety of analytes across a wide range of concentrati The SpectraMax Plus 384 Microplate Spectrophotometer is a versatile and reliable instrument that can measure absorbance in the UV and visible range. Components The main components of SpectraMax and VersaMax readers described in this manual are: ¥ Control panel ¥ Microplate drawer We would like to show you a description here but the site won’t allow us. Which SpectraMax M Series reader do you need? SpectraMax M Series Multi-Mode Microplate Readers 5 Ordering information VWR cat. P. Or scan up to 384 wells at any time to determine the best assay conditions. Fluorescence microplate reader ichroma™ (Boditech Med Inc. Microplate Readers . VersaMax, SpectraMax 340PC384, 190, Plus 384 Microplate Readers User Guide Electromagnetic Compatibility Regulatory for Canada (ICES/NMB-001:2006) This ISM device complies with Canadian ICES-001. A wide range of assays can be performed using a microplate reader including ELISAs, protein cell growth assays, nucleic acid and protein quantification, enzyme activity measurement, immunoassays, and screening of drug compounds and targets, among. . BaneBio - Home of the Scientific Supermarket! We are committed to providing the global scientific community with laboratory equipment, supplies and services of superior quality and value and to ensuring every aspect of every interaction. SoftMax Pro. Additional high-quality filters to supplement your assay wavelength range requirements are available directly from Molecular Devices. It supports a broad wavelength range – from 340 to 750. Microplate Reader Shelf. The Pyrochrome® Assay together with the VersaMax Microplate Reader offers a sensitive and specific method for detecting endotoxin contamination in the production process of the pharmaceutical and medical device industries. The EnSpire microplate reader is an easy-to-use multimode platform for quantitative detection of light-emitting or light-absorbing. New and used Molecular Devices VersaMax's for sale on LabX. Browse all documents within this study via Advanced Search ; List all documents within this study; Document Name and Accession. Wide range of applications The VersaMax reader covers. used. 0 out of 5 $ 3,895. Organon Teknika OTC 40 Photometer Item: 30937. Before dispensing reagents to the microplate, the VersaMax Reader was turned on and SoftMax Pro GxP Software was launched. SpectraMax and VersaMax . E. In SOFTmax PRO, set up a plate section for an excitation scan with no cutoff filter and use the medium PMT setting. The sample is typically placed in a cuvette through which light is sent horizontally. Users can perform spectral scans from 250 nm to 750. 专为科研检测平台量身打造的灵活且强大的小型微孔板读板机(酶标仪),具备终点法和动力学检测模式,标准配置6块滤光片,覆盖蛋白定量、细胞活力、农药残留、ELISA实验等. Molecular Devices VersaMax Microplate Reader;. VersaMax™ Microplate Reader with SoftMax® Pro Software from Molecular Devices LLC. 2: Major areas of the VERSAmax Control Panel Figure 1. Page 1 ™ VERSAmax Tunable Microplate Reader Operator’s Manual for Instruments with Serial Numbers Beginning with BN Molecular Devices Corporation 1311 Orleans Drive Sunnyvale, California 94089 Part # 0112-0084 Rev. Page. no. Quick View. The VersaMax microplate reader bridges the gap between the affordability of filter-based readers and the flexibility of monochromator-based systems. Furthermore, VersaMax is reliable, which means more uptime and lower long-term cost of ownership. . If sample re-measured because CV is higher than threshold then use the lowest CV. 35 ng/ml; standard curve range: 0 - 50 ng/ml; FHS SPECIMEN CHARACTERISTICS: run in duplicate; frozen samples, run on 1st thaw; samples were subjected to 1-3 freeze-thaw cyclesmolecular devices versamax microplate reader; commercial kit including all reagents; vendor: oxis (cat. The VersaMax reads 96-well microplates. The VMax Microplate Reader is capable of reading up to two wavelengths at a time in the visible wavelength spectrum (400nm-750nm), with 4 filter choices included at time of purchase. Page 2 Molecular Devices Corporation warrants this product against defects in material or workmanship as follows: 1) All. The VMax Microplate Reader is capable of reading up to two wavelengths at a time in the visible wavelength spectrum (400nm-750nm), with 4 filter choices included at time of purchase. measured using an absorbance microplate reader. Cultures were grown in a FLUOstar Omega microplate reader (BMG LabTech) at either 25°C or 37°C with continuous orbital shaking at 700 rpm. If you do not have an iLab account you must first make one: AFFORDABLE, TUNABLE MICROPLATE READER FOR 96-WELL FORMAT VersaMax Microplate Reader AFFORDABLE The robot-compatible VersaMax Reader is cost-effective—users never have to buy filters. 3960N First Street, San Jose, CA, 95134). Furthermore, VersaMax is reliable, which means more uptime and lower long-term cost of ownership. The price range of a reader starts at 2. This user guide provides detailed instructions, troubleshooting tips and technical specifications for these instruments. For FET measurements, the filtered reaction mixture (2 μL) was loaded onto the surface. and luminescence microplate reader validation SpectraTest ABS1 Absorbance Validation Package performance tests Qualify the absorbance performance of SpectraMax i3, i3x, M3, M4, M5, M5e, M2, M2e, Plus384, Plus, 190, 340PC, 340PC384, FlexStation 3, and VersaMax readers by testing the specifications that are absolutely critical to. Through a novel touchscreen option, the SUNRISE operates without a PC, saving you space and adding. Wide range of applications The VersaMax reader covers. Molecular Devices Microplate reader VersaMax. The BioTek Synergy HTX is a compact, economical multimode reader for 6- to 384-well microplates and Take3 microvolume plates. The microplate reader is a widely-used instrument that allows for many samples to be simultaneously measured, as if many miniscule experiments were being per. 005 ng/ml; FHS SPECIMEN CHARACTERISTICS: run in duplicate; frozen samples, run on 2nd thaw; samples were subjected to 1-3 freeze-thaw cycles;CV intra-assay: CV intra-assay: (FHS IDs) CV intra FHS IDs: CV Intra-assay final data set. 3: Control PanelVersaMax Microplate Reader An affordable, tunable microplate reader for 96-well format Affordable The robot-compatible VersaMax reader is cost-effective—users never have to buy filters. 00 Read more96 well Thermo Fisher microplate reader, 340-850 wavelength capabilities, filter wheel, onboard software and external PC control. Microplate Readers. After all reactions, the plates were read at 450 nm using a VERSA max microplate reader (Molecular Devices). $495. 2 only) SpectraMax M-series Microplate readers. Microplate Stacker 및 Washer에서 다양한 소모품 및 assay에 이르는 완벽한 고성능 Labware 솔루션입니다. 00 USD. Microplate readers read biological, chemical or physical events that occur on a microtiter plate. Microplate Readers Biotek Synergy 2 Plate Reader Multi-Mode. Preventative maintenance from ATG will keep your SpectraMax® and VersaMax™ microplate readers running smoothly with minimal downtime for as long as. BIOTEK ELX808IU 96 well ABS MicroPlate Reader System w/ GEN5 Anayisis SW, Incubation-New PM testing $2,600. Molecular Devices VersaMax Microplate Reader. 3 mm. Whether you need to measure fluorescence, absorbance, luminescence, or time-resolved fluorescence, or perform AlphaScreen™ assays, we offer. 2. Learn how to operate the VersaMax, SpectraMax 340PC384 and SpectraMax 190 Plus384 microplate readers, which offer fast and accurate absorbance measurements for a variety of assays. SpectraMax® iD3 and iD5 Multi-Mode Microplate Readers. Item VersaMax™ Microplate Reader with SoftMax® Pro Software; Company Molecular Devices LLC; This product is no longer available on Biocompare. 2. And the VERSAmax reader is robotics-compatible. Receive text. VersaMax™ ELISA microplate reader allows for selection of up to two wavelengths at a time for absorbance detection in the visible wavelength range (340 to 850 nm). 0%, 0-2. The VersaMax Absorbance Microplate Reader allows for selection of up to two wavelengths at a time. Over 120 assay protocols are included to speed life science research and drug discovery assay. on the similarities in performance between four single-mode absorbance plate readers: SpectraMax® ABS, SpectraMax® ABS Plus, SpectraMax® 190* and VersaMax™* Microplate Readers. SoftMax® Pro, the industry-leading microplate reader software, is included at no additional charge. Manufacturer: Molecular Devices The Molecular Devices VersaMax Microplate Reader is a high-performance laboratory instrument designed for fast and accurate measurements allowing for selection of up to two wavelengths at a time for absorbance de. So the impact is usually on linearity and the measured absorbance will be lower than the true absorbance. The Monroe Calculating Machine Company was a maker of adding machines and calculators founded in 1912 by Jay R. Select Update Driver. 0 out of 5 $ 2,999. Wide range of applications The VersaMax reader covers. Calibrators were plotted using the 4-parameter curve fit in SoftMax Pro Software. WIDE. Robust, high-value microplate readers that can run samples based on pre-defined protocols and standard filter modes cover the entire visible range for a variety of assays. ) Fast patient sample treatment and saved data search are made possible by the intuitive and user-friendly interface. Narrow bandwidths deliver increased accuracy and enhanced peak resolution. on the similarities in performance between four single-mode absorbance plate readers: SpectraMax® ABS, SpectraMax® ABS Plus, SpectraMax® 190* and VersaMax™* Microplate Readers. Manufacturer: Molecular Devices; Molecular Devices VersaMax Microplate Reader with Toughbook and Software This item has been tested and is in proper working condition Wavelength Range – 340–850 nm Wavelength Selection – Monochromator, tunable i. The Spectramax 250s xenon flash lamp and grating monochromator facilitates direct UV measurement of DNA, RNA, and protein in microplates. Flexible for 6-well to 384-well microplates and cuvettes. Microplate Readers. WinKQCL ® Endotoxin Detection and Analysis Software Version 6 Features. 00 USD BMG FLUOstar Galaxy Microplate Reader $9,999. Molecular Devices SpectraMax M5 Multi-Mode Microplate Reader. SpectraMax Paradigm Multi-Mode Safety Guide VersaMax Microplate Reader An affordable, tunable microplate reader for 96-well format Affordable The robot-compatible VersaMax reader is cost-effective—users never have to buy filters. This user guide provides detailed instructions, troubleshooting tips and technical specifications for these instruments. com FREE DELIVERY possible on eligible purchasesThe SpectraMax® M Series Multi-Mode Microplate Readers are modular and upgradeable with a wide range of high performance capabilities ideal for life science research and drug discovery screening SoftMax® Pro 7. used. Lysotracker. SoftMax® Pro, the industry-leading microplate reader software, is included at no additional charge. FAST AND ACCURATE METERTECH Microplate Reader $3,650. SOFTMAX PRO DATA ACQUISITION MODULE FOR PLA 3. Tunable, filterless flexibility The VersaMax reader uses a grating monochromator to select the wavelength, so the exact wavelength needed can be selected for every assay. Add to Cart. The VersaMax Microplate Reader is supplied with SoftMax® Pro Data Acquistion & Analysis Software, Molecular Devices' industry leading all-in-one data acquisition and analysis software. The Molecular Devices SpectraMax 384 Plus is a UV/Vis spectrophotometer and microplate reader combination for more reliable and fast data reporting with built-in cuvette port and microplate drawer. Perception (Vial Rack Bottom Label 2D Reader) Microscan. Microplate Readers. 33 Dramatic aggregation of Alzheimer A b by Cu(II) is induced by. 75 mm) high. A wide range of assays can be performed using a microplate reader including ELISAs, protein cell growth assays, nucleic acid and protein quantification, enzyme activity measurement, immunoassays, and screening of drug compounds and targets, among. Probe stock solution (1 mM) was diluted in conditioned media to prepare a working solution (75 nM), and cells were. We then validated a protocol wherein the electrical activity of motor neural cultures is measured directly by a voltage sensitive dye and a microplate reader without causing. Videos & Webinars. Microplate readers read biological, chemical or physical events that occur on a microtiter plate. Molecular Devices VersaMax Tunable Microplate Reader. The Molecular Devices Gemini EM is built on the Gemini platform delivering high quality top and bottom reading for both solution and cell based assays. Run a variety of luminometric research applications with the Thermo Scientific Luminoskan microplate luminometer, a compact and robust instrument offering versatile plate formats, fast reading speeds and up to three dispensers. 190-1000 nm. Near bottom. It features a dual-monochromator system, a large dynamic range, and a high-throughput capability. 0 OD. Perkin Elmer Wallac 1420 Victor2 Microplate. Robust, high-value microplate readers that can run samples based on pre-defined protocols and standard filter modes cover the entire visible range for a. 000Abs . SpectraMax ABS and ABS Plus Absorbance ELISA Microplate Readers. Access all the resources, tools and information you need to stay productive. Furthermore, VersaMax is reliable, which means more uptime and lower long-term cost of ownership. . 2. Home > Search Results > Revvity Signals > versa max microplate reader. FilterMax F3 and F5 Multi-Mode; SpectraMax Paradigm® Multi-Mode Detection Platform. Absorbance. Speed Read Mode. ). The VersaMax microplate reader from Molecular Devices bridges the gap between the affordability of filter-based readers and the flexibility of monochromator-based systems. A: Microplate Preparation. Biocompare is the leading resource for up-to-date product information, product reviews, and new technologies for life scientists. Molecular Devices VersaMax Microplate Reader with Toughbook and Software. A standard spectrophotometer measures the absorbance of one sample at a time. Microplate Readers Biotek Synergy H1 Hybrid Microplate Reader. Tunable, filterless flexibility The VersaMax reader uses a grating monochromator to select the wavelength, so the exact wavelength needed can be selected for every assay. Endotoxin assay analysis were obtained by VERSA max microplate reader and WinKOCLTMsoftware (molecular devices, LLC. VERSA MAX-LUNABLE, MOLECULAR DEVICES, MICROPLATE R. Thermo Fisher Scientific. SpectraMax® Microplate Readers and SoftMax® Pro Software. With the VersaMax microplate reader, you will never have to buy another filter. Microscopes and Microplate Instrumentation. Thermo Fisher Scientific enables our customers to make the world healthier, cleaner and safer. ELISA microplate reader, multi-mode, VersaMax™. Gel imaging system (Kodak Gel Logic 100) Our association with the Institute for Plant Genomics and Biotechnology gives access to novel facilities such as-Capillary DNA Sequencer (ABI 3130xl) Real-time PCR Machine (ABI 7900HT & BioRad CFX384) Sonicator (Brason Sonifier 250)The SpectraMax M2e is a dual-monochromator, multi-detection microplate reader with a dual-mode cuvette port and 96 or 384 microplate reading capability. Maurice S. They allow users to measure biological, chemical, and physical reactions, properties, and analytes. More Info. Designed to provide the simplicity, flexibility and power required for advanced data analysis. VersaMax price. It also integrates with the. 00 Add to cart; Molecular Devices Tunable Microplate Reader VersaMax $ 1,495. After selecting the “Pyrochrome® Kinetic” method protocol from the drop-down menu in SoftMax Pro GxP Software, a new data file was created on. Multichannel optics. . Conventions Used in this Manual. With a wavelength. Quick View. Microplate Readers Tecan Infinite F200 Fluorescence Microplate Reader. The VersaMax and SpectraMax 190 read 96-well microplates. WinKQCL ® Software can be used with a compatible microplate reader to run the template and. Tecan Infinite 200 Microplate Reader. bbe 1b) units: ng/ml; minimum detectable dose: <0. Tecan Microplate Reader Spectra FLUOR Plus $ 5,995. Quick View. A standard cuvette, 12 x 75 test tube as well as a 96- or 384-well microplate can be used in analyzing samples. Molecular Devices VersaMax Microplate Reader with Toughbook and Software. SoftMax Pro Software can collect data from one or more microplates or cuvettes and store it in a single data file, using the same or different instrument settings for different microplates or cuvettes. 1 DocumentBrowse all documents within this study via Advanced Search ; List all documents within this study; Document Name and Accession. Clone Screening. The SpectraMax M5e Multi-Mode Microplate Reader features a triple-mode cuvette port, temperature control, microplate shaking, and the industry leading SoftMax Pro. The basic problem caused by stray light (light you don't want, getting into the read) is a falsely low OD seen at the wavelength range of the band where you failed and at higher ODs. The Pyrochrome Assay together with the VersaMax Microplate Reader offers a sensitive and specific method for detecting endotoxin contamination in the production process. Microplate readers read biological, chemical or physical events that occur on a microtiter plate. The wavelength range in the best microplate reader is between 400- 750 nm. Wide range of applications The VersaMax reader covers. The older spectrophotometers did not correct for this effect. This benchmark for UV-visible microplate readers is capable of processing up to 384 samples in a single plate. Biotek Synergy 2 SL Multi-Mode Microplate Reader Specifications. Seed 2000 or 3000 cells per well (depending on the size of these) and incubate for 24 hours at 37°C. Get the most out of SoftMax Pro. The VersaMax Absorbance Microplate Reader measures the optical density (OD) of samples at selected wavelengths in a number of reading modes. Making it possible to perform kinetic analysis of solid. Topics: monroe calculating machine company, monroe calculating machine. SoftMax® Pro Software for Windows 10 and 11 is designed to provide the simplicity, flexibility and power required for advanced data analysis. Environment. Bioz Stars score, Techniques, Protocol Conditions and more for Versa Max Microplate Reader, supplied by Revvity Signals. E. If you really want to minimize your downtime, contact us about a service contract! Preventative maintenance from ATG will keep your SpectraMax® and VersaMax™ microplate readers running smoothly with minimal downtime for as long as possible. SoftMax® Pro Software is the leading solution for microplate reader control and data analysis, where our exclusive INSIDER members help to ensure it remains the most innovative research tool available. Assessment of Plasma Reactive Oxygen Species (ROS) in Plasma. Learn how to operate the VersaMax, SpectraMax 340PC384 and SpectraMax 190 Plus384 microplate readers, which offer fast and accurate absorbance measurements for a variety of assays. The VersaMax microplate reader bridges the gap between the affordability of filter-based readers and the flexibility of monochromator-based systems. With aVersaMax Microplate Reader An affordable, tunable microplate reader for 96-well format Affordable The robot-compatible VersaMax reader is cost-effective—users never have to buy filters. 1. Read up to 2 wavelengths in endpoint or kinetic mode for 96-well plates. AXON Patch-Clamp. WIDE. The Veritas™ software facilitates a quick set-up for the Dual-Luciferase® Reporter Assay with a pre-installed template. SpectraMax® M2 Multi-Mode Microplate Reader MLDVM2 SpectraMax® M2e Multi-Mode Microplate Reader (top and bottom reading) MLDVM2E SpectraMax® M3 Multi-Mode Microplate Reader MLDVM3 Ordering information VWR cat. MAXline Microplate Readers User’s Manual iii Molecular Devices Corporation Instrument Warranty Molecular Devices Corporation warrants this product against defects in material or workmanship as follows: 1) All parts of the MAXline Microplate Reader excluding the lamp assembly are warranted for a SpectraMax190,340PC384,Plus384,VersaMaxMicroplateSpectrophotometersUserGuide 8 0112-0126D ComputerIntegration. Furthermore, optional Magellan™ software packages provide full data reduction capability and are designed to meet FDA regulation 21 CFR Part 11. The Spectramax 190 has an array of data collection modes, including kinetic, endpoint, and spectral scan modes. A wide range of assays can be performed using a microplate reader including ELISAs, protein cell growth assays, nucleic acid and protein quantification, enzyme activity measurement, immunoassays, and screening of drug compounds and targets, among. Home - University of Victoriathat the VersaMax Microplate Reader can detect down to at least 10 ppb melamine. Call 1-800-745-2710. The Varian Cary 50 MPR Microplate Reader is an accessory for the Varian Cary 50 UV/Vis Spectrophotometer and can accurately perform wavelength scans from 190 to 1100 nm in up to 384. absorbance readers. The VersaMax™ Microplate Reader from Molecular Devices bridges the gap tunable microplate reader for 96-well versamax microplate reader, versamax Molecular Devices VersaMax Forums Questions Only Molecular Devices microplate plate readers offer the capability to . A wide range of assays can be performed using a microplate reader including ELISAs, protein cell growth assays, nucleic acid and protein quantification, enzyme activity measurement, immunoassays, and screening of drug compounds and targets, among. VersaMax ELISA Microplate Reader. A wide range of assays can be performed using a microplate reader including ELISAs, protein cell growth assays, nucleic acid and protein quantification, enzyme activity measurement, immunoassays, and screening of drug compounds and targets, among. Product Description. The optical density at 450 nm and 690 nm (reference wavelength) was measured using the Versa Max microplate reader (Molecular Devices, Sunnyvale, CA, USA) to determine a viable cell number. Microplate Readers Tecan Infinite M200 Plate Reader. The temperature of the microplate chamber can be regulated, if desired from 4°C above ambient to 45°C. 1 DocumentUsing a microplate reader, absorbance was measured at 560 nm (VersaMax Microplate Reader, Molecular Devices, CA, USA). AN AFFORDABLE, TUNABLE MICROPLATE READER FOR 96-WELL FORMAT VersaMax Microplate Reader AFFORDABLE The robot-compatible VersaMax Reader is cost-effective—users never have to buy filters. 0 out of 5 $ 2,999-20%. Note: SoftMax Pro Software version 6 and 7 also include a searchable help file within the software. Microplate readers read biological, chemical or physical events that occur on a microtiter plate. 190-1000 nm, tunable in 1 nm increments. on the similarities in performance between four single-mode absorbance plate readers: SpectraMax® ABS, SpectraMax® ABS Plus, SpectraMax® 190* and VersaMax™* Microplate Readers. 75 mm) high. Tristar 3 Multimode Microplate Reader. StakMax Microplate Handling Stacker.